Slimline design, with low profile
Fan-less - noisless operation
Withstands 300VAC for 5 secs
Power factor correction
Optional redundancy function
Wide operating temperature range
Output |
Input |
||||
---|---|---|---|---|---|
Model | Voltage | Current (A) | Power | Input Voltage | Efficiency |
UHP-500-4.2 | 4.2V | 80A | 336W | 90 ~ 264VAC | 89.00% |
UHP-500-5 | 5V | 80A | 400W | 90 ~ 264VAC | 90.00% |
UHP-500-12 | 12V | 41.7A | 500.4W | 90 ~ 264VAC | 94.00% |
UHP-500-15 | 15V | 33.4A | 501W | 90 ~ 264VAC | 94.00% |
UHP-500-24 | 24V | 20.9A | 501.6W | 90 ~ 264VAC | 94.50% |
UHP-500-36 | 36V | 13.9A | 500.4W | 90 ~ 264VAC | 95.00% |
UHP-500-48 | 48V | 10.45A | 501.6W | 90 ~ 264VAC | 95.00% |
UHP-500-55 | 55V | 8.9A | 500W | 90 ~ 264VAC | 95.00% |
UHP-500R-4.2 | 4.2V | 80A | 336W | 90 ~ 264VAC | 89.00% |
UHP-500R-5 | 5V | 80A | 400W | 90 ~ 264VAC | 90.00% |
UHP-500R-12 | 12V | 41.7A | 500.4W | 90 ~ 264VAC | 94.00% |
UHP-500R-15 | 15V | 33.4A | 501W | 90 ~ 264VAC | 94.00% |
UHP-500R-24 | 24V | 20.9A | 501.6W | 90 ~ 264VAC | 94.50% |
UHP-500R-36 | 36V | 13.9A | 500.4W | 90 ~ 264VAC | 95.00% |
UHP-500R-48 | 48V | 10.45A | 501.6W | 90 ~ 264VAC | 95.00% |
UHP-500R-55 | 55V | 8.9A | 500W | 90 ~ 264VAC | 95.00% |